Myocardial Biopsy Model
Myocardial Biopsy
With this model, the myocardial biopsy procedure can be simulated under X-ray fluoroscopy, similar to the set-up in a real cath lab. The transparent heart model enables one to practice the procedure by confirming the direction of the sheath and forceps through both an X-ray image and a camera image.
Using the X-ray image, it is possible to determine if the forceps are facing towards the free wall. The compact camera with a flexible arm can provide a clear image from various angles.
As the material used to simulate the ventricular septum is different from that of the ventricular free wall, it is easy to confirm whether the tissue was removed from the appropriate area after the procedure.
- Basic Set -
Myocardial Biopsy Model
Heart Model for Myocardial Biopsy
The heart shape is designed based on the Four-Chamber Model. The septal part can be replaced. Please contact JMC for details.
Special Tank
Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than six liters of water are required for training.
Pulsatile Pump
Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.
Tube with Sheath (24Fr)
Number of tubes: 1( 24Fr )
Lubricant
Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )
Hoses
Hose with one-touch joint.
- Basic Set -
Myocardial Biopsy Model
Heart Model for Myocardial Biopsy
The heart shape is designed based on the Four-Chamber Model. The septal part can be replaced. Please contact JMC for details.
Special Tank
Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than six liters of water are required for training.
Pulsatile Pump
Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.
Tube with Sheath (24Fr)
Number of tubes: 1( 24Fr )
Lubricant
Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )
Hoses
Hose with one-touch joint.