TAVI Horizontal Model
Structure
Horizontal aortic root anatomy causes difficuty in the valve positioning and delivery system retrieval process in TAVI procedure. This model has increased aortic angulation of 78° as measured between plane of aortic valve annulus and horizontal plane.
Aortic Anatomy variety
- Basic Set -
Heart Model for TAVI
Heart model suitable for practical training in TAVI under X-ray fluoroscopy in the cath lab.
Valve part
One of the valves shown below is included.
Aorta parts
The aorta is expressed by a hard material. When delivered, it will be delivered pre-attached to the tank.
Special Tank for TAVI
Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than 6 liters of water are required for training.
Pulsatile Pump for TAVI
Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.
Tube with Sheath
A tube with sheath for radial approach is contained in the set.Femoral sheath for TAVI catheter is not included.6Fr
Lubricant
Special lubricant for coating the inner surface of the heart model.
1 fl. oz. (lasts for 20 coatings)
Hoses
Hose with one-touch joint.
Tube with Sheath (24Fr)
Number of tubes: 1( 24Fr )
- Basic Set -
Heart Model for TAVI
Heart model suitable for practical training in TAVI under X-ray fluoroscopy in the cath lab.
One of the valves shown below is included.
Valve part
One of the valves shown below is included.
Aorta parts
The aorta is expressed by a hard material. When delivered, it will be delivered pre-attached to the tank.
Special Tank for TAVI
Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than 6 liters of water are required for training.
Pulsatile Pump for TAVI
Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.
Tube with Sheath
A tube with sheath for radial approach is contained in the set.Femoral sheath for TAVI catheter is not included.
6Fr
Tube with Sheath (24Fr)
Number of tubes: 1( 24Fr )
Lubricant
Special lubricant for coating the inner surface of the heart model.
1 fl. oz. (lasts for 20 coatings)
Hoses
Hose with one-touch joint.