HEARTROID EP model facilitates technical training for cat heter manipulation and 3D mapping, which are basic skills required for catheter ablation.
With this model, the Bro ckenbrough Method (atrial septal puncture) guided by ICE(intracardiac echocardiography) can also be simulated. The mode l is appropriate for both the internal jugular and femoral vein approach.
Material
-
Hydrogel series
-
Silicon series
Geometry
Recommended procedures
3D mapping(Geometry Creation)
Hydrogel heart model with conductive property can facilitate the simulation of geometry creation process, which is the fundamental procedure for electrophysiologists. Type1 and 2 are designed to be accessed from IVC through atrial septum, and retrograde approach from the femoral artery is acceptable with Type3.
PVI(Cryoballoon ablation)
HEARTROID PVI model facilitates simulated training of a pulmonary vein isolation procedure, with or without X-ray visualization. Duringcryoballoon catheter ablation, the operator is able to check whether pulmonary vein flow is blocked appropriately using a pulsatile pump which included in the standard set. This model features all four pulmonary veins (RSPV, RIPV, LSPV, LIPV), and ICE (intracardiac echocardiography) is usable when passing through the atrial septum
Lead implantation for coronary sinus and branches
Silicon-based transparent heart model with CS (coronary sinus) facilitates the lead implantation procedure under X-ray fluoroscopy and camera view. Coronary sinus and marginal veins can be visualized with contrast injection
Compatible procedures
Type1 | Type2 | Type3 | ||||
2-ch | 4-ch | venous and arterial approach | ||||
Silicon | Hydrogel | Silicon | Hydrogel | Silicon | Hydrogel | |
3D mapping(geometry creation) | ||||||
ICE imaging | ||||||
PVI with cryoballoon | ||||||
Lead implantation for coronary sinus and branches |
- Basic Set -
Model for EP (Hydrogel series)
Model for EP (Silicon series)
Smart Tank for EP (Hydrogel series)
Smart Tank for EP (Silicon series)
HEARTROID Pump Type-1
Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.
Tube with Sheath (24Fr)
Number of tubes: 1( 24Fr )
Lubricant
Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )
Hoses
Hose with one-touch joint.
- Basic Set -
Model for EP (Hydrogel series)
Model for EP (Silicon series)
Smart Tank for EP (Hydrogel series)
Smart Tank for EP (Silicon series)
Pulsatile Pump
Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.
Tube with Sheath (24Fr)
Number of tubes: 1( 24Fr )
Lubricant
Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )
Hoses
Hose with one-touch joint.