Percutaneous VAD Model
Percutaneous VAD Model

Percutaneous VAD Model

Heart Failure

HEARTROID Percutaneous VAD (ventricular assist device) model is designed for training under X-ray fluoroscopy and camera view. This model can facilitate how to insert the device from femoral or subclavian artery to the appropriate position.

Percutaneous VAD Model

Left ventricle contracts with the pulsatile pump, so it can visualize the comparative situation with or without the support of percutaneous VAD. It can also facilitate the visualization of the coronary flow with X-ray angiography or the camera along with the dye injection.

- Basic Set -

Model for Percutaneous VAD

Model for Percutaneous VAD

Heart model suitable for practical training under X-ray fluoroscopy in the cath lab.

Smart Tank for Percutaneous VAD

Smart Tank for Percutaneous VAD

Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than 6 liters of water are required for training.

HEARTROID Pump Type-2

HEARTROID Pump Type-2

Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.

Artificial Vessel Graft

Artificial Vessel Graft

Tube with Sheath (24Fr)

Tube with Sheath (24Fr)

Number of tubes: 2( 24Fr )

Lubricant

Lubricant

Special lubricant for coating the inner surface of the heart model.
1 fl. oz. (lasts for 20 coatings)

Hoses

Hoses

Hose with one-touch joint.

- Basic Set -

Model for Percutaneous VAD

Model for Percutaneous VAD

Heart model suitable for practical training under X-ray fluoroscopy in the cath lab.
One of the valves shown below is included.

Smart Tank for Percutaneous VAD

Smart Tank for Percutaneous VAD

Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than 6 liters of water are required for training.

HEARTROID Pump Type-2

HEARTROID Pump Type-2

Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.

Artificial Vessel Graft

Artificial Vessel Graft

Tube with Sheath (24Fr)

Tube with Sheath (24Fr)

Number of tubes: 2( 24Fr )

Lubricant

Lubricant

Special lubricant for coating the inner surface of the heart model.
1 fl. oz. (lasts for 20 coatings)

Hoses

Hoses

Hose with one-touch joint.

Contact


Product specifications can be customized and are subject to change without notice.
Please contact JMC for details.